Unitor HPC Extreme 520 Manuel de service

Naviguer en ligne ou télécharger Manuel de service pour Nettoyeurs haute pression Unitor HPC Extreme 520. Unitor HPC Extreme 520 Technical data Manuel d'utilisatio

  • Télécharger
  • Ajouter à mon manuel
  • Imprimer
  • Page
    / 16
  • Table des matières
  • MARQUE LIVRES
  • Noté. / 5. Basé sur avis des utilisateurs
Vue de la page 0

Operation manual
HPC Extreme 520 High Flow
Vue de la page 0
1 2 3 4 5 6 ... 15 16

Résumé du contenu

Page 1 - HPC Extreme 520 High Flow

 Operation manual HPC Extreme 520 High Flow

Page 2 - Contents

Operation From fabrication date 07/2005 on this series is equipped with an emergency STOP (2 a) which must be pushed in case of emergency. After e

Page 3

After Work • Switch off machine by means of the ON/OFF switch (2). • Depressurize spray pistol by shortly opening and closing. • Lock spray pist

Page 4 - Safety Instructions

5. Maintenance and Care Every machine is only as reliable as maintenance is carried out. In order to guarantee reliability and trouble free ope

Page 5

Pre-Filter (micro filter 25/50 µm) Upstreams of the high pressure pump there is a micro filter (6) installed. The filter cartridge to be replaced w

Page 6

6. Electric Wiring Diagrams 7. Technical Data Technical Data E 500-30 Water flow/adjustable 800 - 1800 l/h

Page 7

8. Trouble Shooting Electrical energy can cause severe injuries. Defective electrical compo-nents to be immediately replaced, possible causes fo

Page 9 - Connections

Contents 1. Introduction Page 3 2. Safety Instructions Page 4 – 5 3. Configuration/Operation/Il

Page 10

1. Introduction With your Unitor HPC E520HF high pressure cleaner you have purchased one of the most durable and reliable machines available on the

Page 11

2. Safety Instructions The following instructions to be followed before, during and after work: This instruction manual to be r

Page 12 - Maintenance and Care

Before opening the machine in case of malfunction or emergency, switch off by means of the emergency STOP, respectively the ON/OFF switch and disco

Page 13

3. Configuration, Operation, Illustration The cold water machines of this series mainly comprise of a low speed high pressure inline plunger pump,

Page 15 - Trouble Shooting

4. Start-up / Shut-down Before Start-up: Read and observe operation manual. In order to guarantee proper function and trouble-free operation, th

Page 16

Connections Water Supply Connect water inlet (6) of the machine to water source with a clean hose (diameter see table below). Before connecting wa

Commentaires sur ces manuels

Pas de commentaire